Re: EMS won't stop sending alerts (91 Views)
Reply
Valued Contributor
Vince Laurent
Posts: 450
Registered: ‎02-03-1998
Message 1 of 3 (109 Views)

EMS won't stop sending alerts

A few days ago we got an EMS notice on a power supply.  HP came out and changed it out.  We still get alarms on the old issue.  How do we stop it?

 

CURRENT MONITOR DATA:

Event Time..........: Thu Mar 20 02:50:50 2014
Severity............: CRITICAL
Monitor.............: ia64_corehw
Event #.............: 103001
Summary:

     Power Supply : Failure is detected.

.

.

.

Event Details :

     Event Date  ...................: Mon Mar 17 13:49:07 2014
     Sensor Number .................: 0x41
     Sensor Type ...................: Power Supply

 

We are running HP-UX 11.31 on an RX6600.

Please use plain text.
Honored Contributor
Patrick Wallek
Posts: 13,752
Registered: ‎06-21-2000
Message 2 of 3 (98 Views)

Re: EMS won't stop sending alerts

You  have to clear the EMS events.  Try this:

 

To show what EMS currently sees as down:

 

# /opt/resmon/bin/set_fixed -L

 

To clear all EMS "down" items:

 

# /opt/resmon/bin/set_fixed -n \*

Please use plain text.
Valued Contributor
Vince Laurent
Posts: 450
Registered: ‎02-03-1998
Message 3 of 3 (91 Views)

Re: EMS won't stop sending alerts


Patrick Wallek wrote:

To show what EMS currently sees as down:

 

# /opt/resmon/bin/set_fixed -L

When I did this, as suggested by another posting, there  was nothing "down" and nothing "cleared" and we got the message the next day anyway.

Please use plain text.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation