Testing RAID 1 on ProLiant ML350e (314 Views)
Reply
Occasional Advisor
JonathanAnon
Posts: 17
Registered: ‎07-07-2013
Message 1 of 3 (314 Views)

Testing RAID 1 on ProLiant ML350e

[ Edited ]

Hi Everybody, 

 

We're putting in our first ProLiant server on to a small site next week. The client wants to see a demonstration of how RAID 1 redundancy would work in the case of a hard disk failure. I was thinking of just pulling the disk out of the front drive bay as the server is running (to simulate a disk failure). Then when the client is satisfied with my visual demonstration, I would just put the drive back in to the drive bay and let it rejoin the RAID. 

 

Is there any reason why this would be a bad idea? I mean, is it okay just to pull the disk out and then put it back? 

 

thanks, 

J

 

 

P.S. This thread has been moved from Servers > General to ProLiant Servers (ML,DL,SL). - Hp Forum Moderator

Valued Contributor
LouisH
Posts: 126
Registered: ‎10-24-2012
Message 2 of 3 (237 Views)

Re: Testing RAID 1 on ProLiant ML350e

Hi,

 

By your message, I'm guessing that the server is being moved to a new location.  After booting up, check the ACU or ADU to verify disks are ok and no errors. Then pull out a disk, verify server is still fully up without problems (for your customer's benifit), then re insert disk. disk will be rebuilt from scratch.

 

Regards,

 

Louis

Occasional Advisor
JonathanAnon
Posts: 17
Registered: ‎07-07-2013
Message 3 of 3 (206 Views)

Re: Testing RAID 1 on ProLiant ML350e

Thanks Louis, 

 

that's what I was looking for.. :-)

 

regards, 

 

The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation.