[Smart Array Controler]E200 - POST Error 1794 (751 Views)
Reply
Visitor
Kaelas
Posts: 4
Registered: ‎03-17-2014
Message 1 of 8 (751 Views)

[Smart Array Controler]E200 - POST Error 1794

Hi all,

 

I've a HP Proliant ML310 G4 and Smart Array Controler E200. I've a POST Error 1794. So,  I've replaced the module cache with battery, 2 times ,and upgrade the firmware with the last version 1.86 but same error "battery failed".  

Then,I don't know what to do, can you help me plz?

 

PS : Sorry for my bad english.

Please use plain text.
HP Pro
scharchouf
Posts: 296
Registered: ‎03-07-2013
Message 2 of 8 (741 Views)

Re: [Smart Array Controler]E200 - POST Error 1794

1794-Drive Array - Array Accelerator Battery Charge Low...
...Array Accelerator is temporarily disabled.
Array Accelerator will be re-enabled when battery reaches full charge.
Audible Beeps: None
Possible Cause: The battery charge is below 75 percent. Posted writes are disabled.
Action: Replace the array accelerator board if the batteries do not recharge within 36 powered-on hours.

I am an HP employee
Was the post useful? Click on the white KUDOS! Star
Please use plain text.
Visitor
Kaelas
Posts: 4
Registered: ‎03-17-2014
Message 3 of 8 (727 Views)

Re: [Smart Array Controler]E200 - POST Error 1794

Hi,

 

Thanks for your reply

 

the array accelerator and the cache module are the same, right?

If this is the case, i replaced the array accelerator/cache module with battery 2 times because the first time, i 'd still the same error and i thought the module or the battery cover were defective. So, i still have the same error after the second replacement.

 

Thx

Please use plain text.
HP Pro
scharchouf
Posts: 296
Registered: ‎03-07-2013
Message 4 of 8 (725 Views)

Re: [Smart Array Controler]E200 - POST Error 1794

Please send me an ADU report

I am an HP employee
Was the post useful? Click on the white KUDOS! Star
Please use plain text.
Visitor
Kaelas
Posts: 4
Registered: ‎03-17-2014
Message 5 of 8 (703 Views)

Re: [Smart Array Controler]E200 - POST Error 1794

Hi,

 

Thx for your reply

 

How to generate ADU report? it need a reboot, no?

Please use plain text.
HP Pro
scharchouf
Posts: 296
Registered: ‎03-07-2013
Message 6 of 8 (688 Views)

Re: [Smart Array Controler]E200 - POST Error 1794

-All programs ==> HP System Tools ==> HP Array Configuration Utility  

 

 

 

Diagnostics ==> Generate Diagnostic Report

 

 

I am an HP employee
Was the post useful? Click on the white KUDOS! Star
Please use plain text.
Visitor
Kaelas
Posts: 4
Registered: ‎03-17-2014
Message 7 of 8 (683 Views)

Re: [Smart Array Controler]E200 - POST Error 1794

Hi,

 

here is the report

it is on HP Array Diagnostic Utility

 

Thx

Please use plain text.
HP Pro
scharchouf
Posts: 296
Registered: ‎03-07-2013
Message 8 of 8 (681 Views)

Re: [Smart Array Controler]E200 - POST Error 1794

First of All your server is out of date

Please update it using SPP :

http://h17007.www1.hp.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx

 

after that send me new ADU :)

I am an HP employee
Was the post useful? Click on the white KUDOS! Star
Please use plain text.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation