Re: Siebel 8.0 and Load Runner 9.5 Diagnostics issue (439 Views)
Reply
Occasional Contributor
Posts: 2
Registered: ‎03-07-2008
Message 1 of 5 (479 Views)

Siebel 8.0 and Load Runner 9.5 Diagnostics issue

We are currently trying to use HP Load Runner 9.5 and Diagnostics 8.0 for Siebel 8.0 (HP-UX). The installations, configurations and the rsh connections have been made. SARM logs have been enabled in all app servers and web server (It has been confirmed that the SARM files are being written).

However while after the execution using Load Runner is complete, we are getting the error “ No files found for server ‘server name’ in directory ‘log directory name’ ”.

The Controller and Web server are in the same security zone , while the app servers are in aonther zone. The ports 445, 514, 139 have been opened and rsh and rcp is working from the Controller machine to all the servers.

We have also copied the sarm files from all the servers to the controller machine.
HP Expert
Posts: 1,124
Registered: ‎05-27-2009
Message 2 of 5 (479 Views)

Re: Siebel 8.0 and Load Runner 9.5 Diagnostics issue

Do you want to record scripts against Siebel 8.0 using LR95? If so, it is supported.

If you want to use Siebel Diagnostics with LR95, it is not supported.
Honored Contributor
Posts: 2,861
Registered: ‎04-23-2008
Message 3 of 5 (479 Views)

Re: Siebel 8.0 and Load Runner 9.5 Diagnostics issue

Hi,

Siebel 8.0 is not QA's with LR 9.5.

I suggest you to get in touch with local HP sales and raise a business case to support this.

If you have access to support portal, you can log a product enhancement case.

Based on the impact, product team may release a pacth for all of us.

I think I have heard of one similar case recently !

~~Shivaram
Highlighted
Occasional Visitor
Posts: 1
Registered: ‎02-28-2012
Message 4 of 5 (439 Views)

Re: Siebel 8.0 and Load Runner 9.5 Diagnostics issue

Hi,

I'm running LR 11 Patch 3 (Siebel ARM Mediator version 11.0.0.8859) against Siebel SIA 8.1.1.4 and I have the same problem.

 

LR diagnositcs doesn't file the files.

Though the exist and are generated correctly by Siebel

 

Attached is a log file.

 

David

Visitor
Posts: 2
Registered: ‎07-30-2012
Message 5 of 5 (377 Views)

Re: Siebel 8.0 and Load Runner 9.5 Diagnostics issue

Hi All,
Has anyone successfully automated Siebel 8.1.1.4 functional testing (or LoadRunner) for that matter? The add-in claims these following versions only: Siebel 7.0.x, 7.5.x, 7.7.x, 7.8.x, 8.0.x, 8.1.1.1
thanks
Fred