Error while running flow in OO 10 - Exception occured during navigation calculation (178 Views)
Reply
Valued Contributor
Dimiter Todorov
Posts: 109
Registered: ‎03-02-2010
Message 1 of 1 (178 Views)

Error while running flow in OO 10 - Exception occured during navigation calculation

This is a flow that I upgraded from OO 9 to OO 10.

 

This flow is really hard for me to debug as we only have 2 windows during which to test. 6PM and 2AM. So im hoping maybe someone can shed some light.

 

After one of the subflow runs this error is thrown.

The subflow uses OGSH to stop a service.

The subflow runs fine, appears that central pukes right after it.

 

{"error_message":"Exception occurred during navigation calculation. ","context":"e49ae26c-a7f3-4554-9aa5-dd2621b237fa
Step Context:
CURRENT_STEP_NAME=Stop Websphere
CURRENT_STEP_UUID=ab9d8e6b-507b-4146-98a6-c1ad33ee5126
CURRENT_STEP_UUID_WITH_DEPTH=ab9d8e6b-507b-4146-98a6-c1ad33ee5126_0
oRetryCount=5
oRetrySleep=10
oServiceCommand=STOP
oServiceHost=sanitizedservername01.domain.ad-GDC
oServiceName=\"IBMWAS70Service - sanitizedservername01Node01\"
Flow Context:
INTERNAL_OPERATION_PRIMARY_OUTPUT=
SERVICE_NAME: IBMWAS70Service - sanitizedservername01Node01
TYPE : 10 WIN32_OWN_PROCESS
STATE : 3 STOP_PENDING
(STOPPABLE, NOT_PAUSABLE, ACCEPTS_SHUTDOWN)
WIN32_EXIT_CODE : 0 (0x0)
SERVICE_EXIT_CODE : 0 (0x0)
CHECKPOINT : 0x1
WAIT_HINT : 0x1e848

REP01-saname=sanitizedservername01.domain.ad-GDC
REP01-svc-sia=BOE120SIAsanitizedservername01
REP01-svc-websphere=\"IBMWAS70Service - sanitizedservername01Node01\"
REP02-saname=SANITIZEDSERVERNAME02.domain.ad-GDC
REP02-svc-db2=DB2
REP02-svc-sia=BOE120SIASANITIZEDSERVERNAME02
REP03-saname=SANITIZEDSERVERNAME03.domain.ad-GDC
REP03-svc-sia=BOE120SIASANITIZEDSERVERNAME03
REP04-saname=SANITIZEDSERVERNAME04.domain.ad-GDC
REP04-svc-sia=BOE120SIASANITIZEDSERVERNAME04
RS_Previous_Response=readyforboot
RS_Previous_Transition=readyforboot
RS_Previous_Transition_Annotation=
SA-password=******
SA-rebootTimeout=1800000
SA-user=todorovdi
SVC-timeout-count=10
SVC-timeout-wait=10
bootFilepath=D/BOOT_TRIGGER/BOOT*.TXT
bootFileserver=sanitizedservername01.domain.ad-GDC
numWait30Sec=410
oRetryCount=5
oRetrySleep=10
oServiceCommand=STOP
oServiceHost=sanitizedservername01.domain.ad-GDC
oServiceName=\"IBMWAS70Service - sanitizedservername01Node01\"
overrideJRAS=RAS_OPERATORS_MGMT
FlowOutput Context:
Global Context:
CENTRAL_URL=http://localhost:8080/oo
execution_thread_id=
execution_userid=todorovdi
run_id=213700001
System Context:
INTERNAL_FLOW_RESPONSE_NAME=null
INTERNAL_FLOW_RESPONSE_TYPE=null
INTERNAL_FLOW_PRIMARY_OUTPUT=null
EXECUTION_STEP_ERROR_KEY=Exception occurred during navigation calculation.
","execution_status":"SYSTEM_FAILURE"}

 

 

 