ignite adding client

hi,

I installed new IGNITE

 

 

# swlist -l product|grep -i ignite
  Ignite-UX             C.7.7.93       HP-UX System Installation Services
# swlist -l depot | grep -i recover
  /var/opt/ignite/depots/recovery_cmds
#
 

When i install new clients its generating error messages:-------

 

ERROR swinstall failed to install recovery tools from:

"billdev1:/var/opt/ignite/depots/recovery_cmds

 

this is my server nfs entry

# more /etc/dfs/dfstab
#       place share(1M) commands here for automatic execution
#       on entering init state 3.
#
#       share [-F fstype] [ -o options] [-d "<text>"] <pathname>
#       .e.g,
#       share  -F nfs  -o rw=engineering  -d "home dirs"  /home
share -F nfs -o anon=2 /var/opt/ignite/clients
share -F nfs -o anon=2  /var/opt/ignite/depots/recovery_cmds
share -F nfs -o anon=2 /var/opt/ignite/clients/appsdev2
#
 

Please suggest me ..................

 

 

thanks

aamir

 

Please use plain text.
Acclaimed Contributor
Torsten.
Posts: 23,253
Registered: ‎10-02-2001
Message 2 of 6 (248 Views)

Re: ignite adding client

You should install the Installation Utilities too, looks like this:

 

  Ignite-UX-11-11       C.7.5.142      HP-UX Installation Utilities for Installing 11.11 Systems
  Ignite-UX-11-23       C.7.5.142      HP-UX Installation Utilities for Installing 11.23 Systems
  Ignite-UX-11-31       C.7.5.142      HP-UX Installation Utilities for Installing 11.31 Systems


Hope this helps!
Regards
Torsten.

__________________________________________________

There are only 10 types of people in the world -
those who understand binary, and those who don't.

__________________________________________________

No support by private messages. Please ask the forum!

If you feel this was helpful please click the KUDOS! star in the left column!   
Please use plain text.
Regular Advisor
Aamir14
Posts: 114
Registered: ‎07-04-2011
Message 3 of 6 (233 Views)

Re: ignite adding client

Hi,

 

 

I already installed older version 

 

│            Ignite-UX-11-11  ->   C.7.7.93        HP-UX Installation Utili │ │
││            Ignite-UX-11-23  ->   C.7.7.93        HP-UX Installation Utili │ │
││            Ignite-UX-11-31  ->   C.7.7.93        HP-UX Installation Utili
 
but still same error
 
thanks
aamir
Please use plain text.
Regular Advisor
Aamir14
Posts: 114
Registered: ‎07-04-2011
Message 4 of 6 (217 Views)

Re: ignite adding client

Hi,

 

I installed ignite an new server

i added two clents both clients are successsfully installed 

 

but i also add four new clients .but they are not installed properly 

its shown ERROR messages 

for example:-----

ERROR

rcmd_af: connect: prodpyrl.mpmkvvcl.com connection refused

 

 

second error:---

 

Warning: untrusted X11 forwarding setup failed: xauth key data not
generatedwarning: no xauth data&colon; using fake authentication data for
X11 forwarding.mnr_UI Couldn't bring the initial window. This may
occur when you specify an incorrect display.ERROR:   The interactive
UI failed to start. Check your terminal type.

 

I already x11 allow on sshd config file:------

 

     X11Forwarding yes
 
X11DisplayOffset 10
KerberosAuthentication yes
Protocol 2,1
 
this is my ssh and ignite version:-----
 
# swlist | grep -i secureshell
  SecureShell                   A.06.20.006    HP-UX Secure Shell
# swlist -l product|grep -i ignite
  Ignite-UX             C.7.11.444     HP-UX System Installation Services
 
 
Server and Clients are same ignite version and enabled X11 forfarding.
 
Please suggest me what is  a actual problem...
 
Thanks
Aamir 
 
 
 
 

 

 

Please use plain text.
Regular Advisor
Aamir14
Posts: 114
Registered: ‎07-04-2011
Message 5 of 6 (210 Views)

Re: ignite adding client

Hi,

 

Also Kindly see the IGNITE logs....

 

WARNING: Client uatdata1 is waiting for installation.  Since the server started
         checking, the client's logfile has not been updated in 45 minutes.
         The timeout in effect is 20 minutes.
 
WARNING: Client prodata1 is waiting for installation.  Since the server started
         checking, the client's logfile has not been updated in 45 minutes.
         The timeout in effect is 20 minutes.
 
ERROR:   rcmd_af: connect: prodpyrl.mpmkvvcl.com: Connection refused
 
ERROR:   rcmd_af: connect: prodpyrl.mpmkvvcl.com: Connection refused
 
 
=======  11/05/13 17:34:17 IST  End HP-UX Install Server
 
 
 
 
=======  11/06/13 14:50:20 IST  Begin HP-UX Install Server
         @(#)ignite/ignite user interface (opt) Revision:
         /branches/IUX_RA1009/ignite/src@81712 Last Modified: 2010-07-23
         02:35:40 -0600 (Fri, 23 Jul 2010)
 
 
 
=======  11/06/13 14:50:27 IST  Begin HP-UX Install Server
         @(#)ignite/ignite user interface (opt) Revision:
         /branches/IUX_RA1009/ignite/src@81712 Last Modified: 2010-07-23
         02:35:40 -0600 (Fri, 23 Jul 2010)
 
 
 
=======  11/06/13 17:50:46 IST  Begin HP-UX Install Server
         @(#)ignite/ignite user interface (opt) Revision:
         /branches/IUX_RA1009/ignite/src@81712 Last Modified: 2010-07-23
         02:35:40 -0600 (Fri, 23 Jul 2010)
 
 
Program completed successfully.
       * The system recovery archive for "uatdata2" is "Complete".
 
       * The system recovery archive for "appsdev2.mpmkvvcl.com" is "Complete".
 
ERROR:   rcmd_af: connect: prodpyrl.mpmkvvcl.com: Connection refused
 
ERROR:   rcmd_af: connect: prodpyrl.mpmkvvcl.com: Connection refused
 
ERROR:   rcmd_af: connect: prodpyrl.mpmkvvcl.com: Connection refused
 
 
=======  11/06/13 18:05:44 IST  End HP-UX Install Server
 
 
 
 
=======  11/07/13 11:12:52 IST  Begin HP-UX Install Server
         @(#)ignite/ignite user interface (opt) Revision:
         /branches/IUX_RA1009/ignite/src@81712 Last Modified: 2010-07-23
         02:35:40 -0600 (Fri, 23 Jul 2010)
 
 
Program completed successfully.
       * The system recovery archive for "uatdata2" is "Complete".
 
       * The system recovery archive for "appsdev2.mpmkvvcl.com" is "Complete".
 
ERROR:   rcmd_af: connect: prodpyrl.mpmkvvcl.com: Connection refused
 
WARNING: Client uatdata1 is waiting for installation.  Since the server started
         checking, the client's logfile has not been updated in 20 minutes.
         The timeout in effect is 20 minutes.
 
WARNING: Client prodata1 is waiting for installation.  Since the server started
         checking, the client's logfile has not been updated in 79 minutes.
         The timeout in effect is 20 minutes.
 
WARNING: Warning: untrusted X11 forwarding setup failed: xauth key data not
         generatedWarning: No xauth data; using fake authentication data for
         X11 forwarding.       * Boot device is:
         0/6/0/0/0/0/4/0/0/0.0x0.0x4000000000000000
 
WARNING: Warning: untrusted X11 forwarding setup failed: xauth key data not
         generatedWarning: No xauth data; using fake authentication data for
         X11 forwarding.mnr_ui: Couldn't bring up the initial window. This may
         occur whenyou specify an incorrect display.ERROR:   The interactive UI
         failed to start.  Check your terminal type.
 
 
=======  11/07/13 12:55:44 IST  End HP-UX Install Server
 
 
 
 
=======  11/07/13 12:55:47 IST  Begin HP-UX Install Server
         @(#)ignite/ignite user interface (opt) Revision:
         /branches/IUX_RA1009/ignite/src@81712 Last Modified: 2010-07-23
         02:35:40 -0600 (Fri, 23 Jul 2010)
 
 
Program completed successfully.
       * The system recovery archive for "uatdata2" is "Complete".
 
       * The system recovery archive for "appsdev2.mpmkvvcl.com" is "Complete".
 
WARNING: Warning: untrusted X11 forwarding setup failed: xauth key data not
         generatedWarning: No xauth data; using fake authentication data for
         X11 forwarding.mnr_ui: Couldn't bring up the initial window. This may
         occur whenyou specify an incorrect display.ERROR:   The interactive UI
         failed to start.  Check your terminal type.
 
WARNING: Warning: untrusted X11 forwarding setup failed: xauth key data not
         generatedWarning: No xauth data; using fake authentication data for
         X11 forwarding.mnr_ui: Couldn't bring up the initial window. This may
         occur whenyou specify an incorrect display.ERROR:   The interactive UI
         failed to start.  Check your terminal type.
 

Thnaks

Aamir

Please use plain text.
HP Pro
pradeep m
Posts: 154
Registered: ‎12-08-2010
Message 6 of 6 (193 Views)

Re: ignite adding client

ERROR

> rcmd_af: connect: prodpyrl.mpmkvvcl.com connection refused

 

For the above error message, check the below in the clients with issues

+ Make sure the login and shell are uncommented.

/etc/inetd.conf  

login        stream tcp6 nowait root /usr/lbin/rlogind  rlogind 
shell        stream tcp6 nowait root /usr/lbin/remshd   remshd 

/etc/services 
# grep login /etc/services    
login        513/tcp                 # remote login   

Port 513 needs to be enabled.

 

If any changes to /etc/inetd.conf are made inetd -c needs to be run for the changes to take effect.

 

Regards,
Pradeep