Ignite Net recovery on PA-RISC and IAc (143 Views)
Reply
Regular Advisor
subodhbagade
Posts: 132
Registered: ‎06-08-2008
Message 1 of 1 (143 Views)

Ignite Net recovery on PA-RISC and IAc

 

Hello Experts ,

Need your inputs on ignite recovery on PA and IA system.

 

I have setup new Ignite server and added clients for recovery and able to take the ignite backup @ Ignite server .  All the clients and server having saame version of ignite software C.7.16.283.

Now I have challenges during recovery  ,

 

I have observed , while running make_net_recovery ,  it takes the first LAN interface’s MAC address irrespective we give the MAC address of PRI Interface while adding client to Ignite server . many times  first MAC / interface might be not having physical connection or it is in different subnet than ignite server  and due to which we cannot perform recovery .

Our ignite server and clients are not on same subnet / vlan and due to which I cannot run the bootpquery

 

Client# /usr/sbin/bootpquery MAC_of_cleint  ether -s server

bootpquery: Bootp servers not responding!

 

>> Ignite server and clients should be on same subnet/Vlan is that condition for recovering PA-RISC ? also applicable for IA-Itanium architecture ?

>>  How to recover system in case if server and clients are on different subnet ?

>> while searching doc , I got  “ Boot HELPER “ we can set  to client’s subnet and that way we can recover the client. For which we have to install “Ignite-UX.MinimumRuntime “ followed by

#instl_adm -t Ignite-UX_server_IP

#instl_adm –d

>> what are exact steps  to configure BOOT HELPER on HPUX server ?

>> Steps to configure boot helper on Non-HPUX like LINUX and how does it works.

>> In case , if we do not have Boot helper and client is on different subnet and due to some reason client get crashed ? then can we just recover the system after requesting network team to change the subnet/Vlan of client to same as server , followed by recovery procedure ? Can this be a work around ?

 

Thanks in advance !

 

~SVB

 

 

 

Please use plain text.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation