Re: Problem of Migration From HP3000 serie 70 O.S MPE 5 Delta (version MPE G03.08) to HPe3000 A500 Class (232 Views)
Reply
Super Advisor
meekrob
Posts: 375
Registered: ‎02-24-2003
Message 1 of 3 (232 Views)

Problem of Migration From HP3000 serie 70 O.S MPE 5 Delta (version MPE G03.08) to HPe3000 A500 Class

Dear All,

We are facing a problem of Data Migration from
From HP3000 serie 70 O.S MPE 5 Delta (version MPE G03.08) to HPe3000 A500 Class.
Please find below the error message we've encountered while during migration.

1°) While trying to install MM3000 on A500 server by executing the command restore @.@.@, the following error occured.

-UNRESOLVED PROGRAM EXTERNAL REALLOCATE
-SL BINDING ERROR (load error 27)
-RUN *TIP ;LIB=G ;"SAI MMCUIS"
Le programme TIP est en compatible mode
-UNABLE TO LOAD PROGRAM TO BE RUN (CIERR 625)

2°)While trying to install the new version of MM3000 MM3000 (MM3000 version 2000 / Native mode ), teh following error appeared:

a)-UNRESOLVED GSL EXTERNAL REALLOCATE
-SL BINDING ERROR (load error 27)
-RUN *AC4000P ;LIB=p
- program AC4000P in compatible mode.
- unable to load program to be run.. (CIERR 625)

b)-PROCESS QUIT; PARAM=-1041
ABORT TIP.SYSPGM.TOOL2000
Program TIP in native mode
-NM SYS a.ooebf70 dbg_abort_trace+$28
-NM PUB37d.00119a7c reallocate+$140
-NM PROG4a6.00019b38 reallocate now+$124
- program terminated in an error state. (CIERR 976)

Please advise how to sort out this problem.

Thanks a lot for your usual cooperat
Honored Contributor
Kwan Fong, Emile
Posts: 1,162
Registered: ‎07-10-2000
Message 2 of 3 (232 Views)

Re: Problem of Migration From HP3000 serie 70 O.S MPE 5 Delta (version MPE G03.08) to HPe3000 A500 Class

You may want to contact ExeGeSys, company which provides support for MM3000.

Worldwide Headquarters (US)

Tel: 801-538-0222
Toll free: 877-393-4379
Internet: http://exegesys.com/

Europe Office VDS-Computing (Belgium)

Tel: 32-9-349-37-60
Fax: 32-9-349-20-14
www.VDS-Computing.com

King is the customer!
Occasional Visitor
john hohn
Posts: 1
Registered: ‎02-14-2007
Message 3 of 3 (232 Views)

Re: Problem of Migration From HP3000 serie 70 O.S MPE 5 Delta (version MPE G03.08) to HPe3000 A500 Class

Hello,

I have encounterd a similar problem running MM3000 (TIP) on MPE 7.5. The abort and stack dump is very similar. Did you resolve this problem? If so, can you provide information on this please?

Thanks,
John