Re: ESXi5 BL465c G1 PSOD when using embedded iSCSI BCM5706S NICs (443 Views)
Reply
Occasional Advisor
LBSDS
Posts: 9
Registered: ‎05-13-2010
Message 1 of 5 (515 Views)

ESXi5 BL465c G1 PSOD when using embedded iSCSI BCM5706S NICs

[ Edited ]

PSOD when adding iSCSI target IP address to BL465c G1 iSCSI NIC

 

When adding iSCSI target IP address to BL465c G1 iSCSI NIC 0 (the first embedded NIC, it crases wth a PSOD!

 
I am even using the ISO installation image provided by the link here in the VMware site that is branded an HP version of the ESXi hypervisor.

 
I also ensure all my firmware and drivers were up to date.

 
attached is the PSOD...

 
What could be happening here?

 ESXi5_BL465c_BCM5706S_iSCSI_PSOD.PNG

HP Pro
Suman_1978
Posts: 1,047
Registered: ‎12-07-2010
Message 2 of 5 (479 Views)

Re: ESXi5 BL465c G1 PSOD when using embedded iSCSI BCM5706S NICs

Hi,

 

Have you seen this forum, may be you will get some idea.

http://communities.vmware.com/thread/310758

 

Thanks

HP Pro
indus
Posts: 150
Registered: ‎12-08-2010
Message 3 of 5 (467 Views)

Re: ESXi5 BL465c G1 PSOD when using embedded iSCSI BCM5706S NICs

Hi,

 

Try renaming the vmkiscsid.db file which is at /etc/vmware/vmkiscsid/vmkiscsid.db and reboot the host and configuring it again.

 

If the issues still exists, it could be a issue with network, cloud you brief on the network configuration.

 

Thanks,

Jagadish

-----------------
Was the post useful? Click on the white KUDOS! Star on the left side of this post.
For HP Guided Troubleshooting; http://www.hp.com/support/hpgt

 

-----------------
I am an HP employee.
Was the post useful? Click on the white KUDOS! Star on the left side of this post.
Occasional Advisor
LBSDS
Posts: 9
Registered: ‎05-13-2010
Message 4 of 5 (463 Views)

Re: ESXi5 BL465c G1 PSOD when using embedded iSCSI BCM5706S NICs

Would you still suggest this considering that if I use the software initiator I have no difficulty reaching the storage target?

What does this file do?
HP Pro
indus
Posts: 150
Registered: ‎12-08-2010
Message 5 of 5 (443 Views)

Re: ESXi5 BL465c G1 PSOD when using embedded iSCSI BCM5706S NICs

Hi,

 

The file I had mentioned is the file which holds all the configuration details of the iSCSI on the host, so by renaming the file and rebooting you start configuring from the scratch.

 

Also on BL465c G1 server onboard NICs I doubt if by default iSCSI is supported, as there was an additional license to enable the same. (I am not sure on this part, but please check with product expert)

 

Thanks,

Jagadish

 

-----------------
I am an HP employee.
Was the post useful? Click on the white KUDOS! Star on the left side of this post.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation.