Virtual Connect FlexFabric modules without X-links (337 Views)
Reply
Neighborhood Admin
chuckk281
Posts: 3,134
Registered: ‎01-09-2007
Message 1 of 1 (337 Views)

Virtual Connect FlexFabric modules without X-links

Vasyl had a customer situtation:

 

*****************

 

Hi community,

 

Customer needs to have four 1Gb RJ-45 uplinks per FlexFabric module (total of two modules), so cross-link ports between modules will not be used. Is it supported config?

 

*************

 

Input from Robert:

 

**************

 

This is not supported.  You may however use one or two external 10G connections using X1-X4 ports between the adjacent modules to achieve the required stacking links.

 

**************

 

Other comments or suggestions?

 

Please use plain text.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation