Re: Power profile bios setting questions (510 Views)
Reply
Neighborhood Admin
chuckk281
Posts: 3,089
Registered: ‎01-09-2007
Message 1 of 2 (524 Views)

Power profile bios setting questions

Question from Jenny:

 

************

 

Is there any way to get the HP power profile bios setting thru Insight Control/SIM or script? And also be able to change it to maximum performance ?

 

****************

 

Great info from Dave:

 

*************

 

Below is the sample from the iLO scripting sample.

Change the user/password and the number in red to the power setting you need…

 

I use this for blades in VDI.

 

<!--         RIBCL Sample Script for HP Lights-Out Products          -->

<!--Copyright (c) 2005,2007 Hewlett-Packard Development Company, L.P.-->

 

<!-- Description:  This is a sample XML script to set the Power      -->

<!--               Regulator feature on the host server in           -->

<!--               Integrated Lights-Out (iLO)                       -->

 

<!--               The values are                                    -->

<!--                     1 = OS Control Mode (Disabled Mode for iLO) -->

<!--                     2 = HP Static Low Power Mode                -->

<!--                     3 = HP Dynamic Power Savings Mode           -->

<!--                     4 = HP Static High Performance Mode         -->

<!--               Note: Value 4 is availble only for iLO 2 firmware -->

<!--                     version 1.20 and later.                     -->

<!--                     Some servers only support subset of the     -->

<!--                     values.                                     -->

 

<!-- NOTE:  You will need to replace the USER_LOGIN and PASSWORD     -->

<!--        values with values that are appropriate for your         -->

<!--        environment.                                             -->

 

<!--        Use CPQLOCFG.EXE ver 2.26 or greater with this script.   -->

 

<!--        This script was written for iLO 2 firmware version 1.30  -->

<!--        release.                                                 -->

 

<!--        See "HP Integrated Lights-Out Management Processor       -->

<!--        Scripting and Command Line Resource Guide" for more      -->

<!--        information on scripting and the syntax of the RIBCL     -->

<!--        XML.                                                     -->

 

<!--        Firmware support infomation for this script:             -->

<!--            iLO 2 - Version 1.10 or later.                       -->

<!--              iLO - Version 1.80 or later.                       -->

<!--         RILOE II - None.                                        -->

 

<RIBCL VERSION="2.0">

  <LOGIN USER_LOGIN="adminname" PASSWORD="password">

  <SERVER_INFO MODE="write">

    <!-- Modify the HOST_POWER_SAVER attribute to modify power saver on the host server -->

    <SET_HOST_POWER_SAVER HOST_POWER_SAVER="4"/>

  </SERVER_INFO>

  </LOGIN>

</RIBCL>

 

*************

 

Any other comments for Jenny?

Please use plain text.
Neighborhood Admin
chuckk281
Posts: 3,089
Registered: ‎01-09-2007
Message 2 of 2 (510 Views)

Re: Power profile bios setting questions

Input from Juha:

 

***************

 

There is also a bit easier way and a place for promoting the usage of Insight Control features:

 

1. Using Insight Control and access to servers (which need to be using iLO advanced licensed, which is part of Insight Control anyway).

 

2. Start Data Center Power Control from Tools  - go to the Define Rules

 

webpic153.jpg

 

Define your targets, e.g.

 

Name: LOW all VM hosts (this would be most likely to be Collection or rules later on)

 

New Step: Action: Power Level – Low Power / Or what you want

 

Act on Systems: where (your conditions here, I have exception for Gate server, as I do not have iLO access for that)

 

Your screen should look like this:

 

webpic154.jpg

 

 

Save rule.

 

Test rule (use simulate) – this is excellent place to show to customers difference of using scripts compared to HP tools – that being said, scripts can be capsulated to the DCPC tool itself…

 

For creating opposite, just copy rule, rename it and you are done.

 

************************

Please use plain text.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation