Re: FlexNIC FCoE using B22HP FEX and Nexus 5596 (498 Views)
Reply
Valued Contributor
Todd Coniam
Posts: 58
Registered: ‎09-22-2010
Message 1 of 2 (542 Views)

FlexNIC FCoE using B22HP FEX and Nexus 5596

[ Edited ]

Anyone know how FCoE is implemented using the FlexNICs on a BL460c Gen 7/8 blade and the Cisco B22HP fabric extender module connected to a Nexus 5596?

 

Can the FlexNICs be partitioned into virtual NIC's (like they can be on Virtual Connects and FlexFabric) to partition the bandwidth used by Ethernet and FCoE, or is it just a single 10Gb pipe?

 

We've had no success in finding documents describing how this is supposed to work...

Trusted Contributor
Casper42
Posts: 279
Registered: ‎10-07-2010
Message 2 of 2 (498 Views)

Re: FlexNIC FCoE using B22HP FEX and Nexus 5596

Its not well documented on the HP side because its usually all controlled from the Nexus side of the house on the upstream 5596.

You will get 1 storage and 1 network function per port. So a 460 will be 2 NICs and 2 FCoE functions as an example but thats it. The additional FlexNICs are specific to Virtual Connect.

Past that I am not really sure about how to configure the bandwidth or settings as I have no experience managing Nexus switches. But there is no difference between a Rackmount server with a CNA connected directly into the 5596 vs the Blade connected to the B22HP FEX from what I understand.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation.