Problem I / O mismatch detected, BL460c G6 Blade c7000 (2680 Views)
Reply
Super Advisor
JuanCG
Posts: 257
Registered: ‎08-03-2008
Message 1 of 3 (2,680 Views)
Accepted Solution

Problem I / O mismatch detected, BL460c G6 Blade c7000

Hi all, I have a problem in a c7000 blade chassis HP.

The configuration of the interface modules is:

Bay1-HP VC-Enet Module 1/10Gb
Bay2 - HP VC-Enet Module 1/10Gb
Bay3 - Brocade 4/12 SAN Switch for HP c
Bay4 - Brocade 4/12 SAN Switch for HP c

OnBoard Version: Firmware Version: 3.70

When I connect a blade of this type:

Model: ProLiant BL460c G6
Manufacturer: HP
Part Number: 507780-B21
Mezz 1
Model: QLogic iSCSI adapter QMH4062
Manufacturer: QLogic
Part Number: 488074-B21
Product View: 0A


When the QLogic FC card is plugged in Position 1, I get this error:

 

1


I / O mismatch detected. Plesase see port mapping information

 

2

thank you very much

Honored Contributor
PGTRI
Posts: 495
Registered: ‎01-19-2012
Message 2 of 3 (2,672 Views)

Re: Problem I / O mismatch detected, BL460c G6 Blade c7000

[ Edited ]

hi,

 

It looks that You are trying to connect a ethernet mezzanine card to a fibre channel VC module.

 

QMH4062 is a ethernet mezzanine card.

 

Thanks

 

regards,

How to Say Thank You? Just click the KUDOS Star!
Super Advisor
JuanCG
Posts: 257
Registered: ‎08-03-2008
Message 3 of 3 (2,663 Views)

Re: Problem I / O mismatch detected, BL460c G6 Blade c7000

PGTRI Hello, thanks for answering, you're right, it was a mistake of mine, I did not watch the card.

thank you very much

The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation.