Re: c-p-u error (299 Views)
Reply
Advisor
Posts: 34
Registered: ‎04-21-2012
Message 1 of 4 (333 Views)

c-p-u error

[ Edited ]

Hi

when i have add cell 3 to join the partition i see this error.please help 

 

Error: The CPU module number of cell 3 (67) and cell 0 (69) do not match . my server is rp 8420.

 

Honored Contributor
Posts: 6,271
Registered: ‎12-02-2001
Message 2 of 4 (314 Views)

Re: c-p-u error

Is the model of the CPUs in cell 3 different from the CPUs in cell 0?

 

All the CPUs in a single partition must be the same model.

MK
Advisor
Posts: 34
Registered: ‎04-21-2012
Message 3 of 4 (309 Views)

Re: c-p-u error

Hi

tanks for help

 

all cpu model is similar.ab537a

 

 

HP Pro
Posts: 51
Registered: ‎11-16-2010
Message 4 of 4 (299 Views)

Re: c-p-u error

[ Edited ]

Hi,

 

can you please switch on all cells (MP:CM> PE) and provide the following data?

  MP:CM> PS  (on all cells)

  MP:CM> DF  (dump - all)

 

This data should show if there is any compatibility issue.

 

 

Kind Regards

Holger

I am an HP employee.
Was this post useful? - You may click the KUDOS! Star.

I work for HP.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation.