c-p-u error

[ Edited ]

Hi

when i have add cell 3 to join the partition i see this error.please help 

 

Error: The CPU module number of cell 3 (67) and cell 0 (69) do not match . my server is rp 8420.

 

Please use plain text.
Honored Contributor
Matti_Kurkela
Posts: 6,271
Registered: ‎12-02-2001
Message 2 of 4 (185 Views)

Re: c-p-u error

Is the model of the CPUs in cell 3 different from the CPUs in cell 0?

 

All the CPUs in a single partition must be the same model.

MK
Please use plain text.
Advisor
godfather-1
Posts: 34
Registered: ‎04-21-2012
Message 3 of 4 (180 Views)

Re: c-p-u error

Hi

tanks for help

 

all cpu model is similar.ab537a

 

 

Please use plain text.
HP Pro
Holger G
Posts: 51
Registered: ‎11-16-2010
Message 4 of 4 (170 Views)

Re: c-p-u error

[ Edited ]

Hi,

 

can you please switch on all cells (MP:CM> PE) and provide the following data?

  MP:CM> PS  (on all cells)

  MP:CM> DF  (dump - all)

 

This data should show if there is any compatibility issue.

 

 

Kind Regards

Holger

I am an HP employee.