Re: IPC Read Error System error: [10053] Software caused connection abort (8914 Views)
Reply
Frequent Advisor
Le Coq Manuel
Posts: 53
Registered: ‎09-03-2009
Message 1 of 23 (10,061 Views)
Accepted Solution

IPC Read Error System error: [10053] Software caused connection abort

hI,

 

Im a cell manager cell.ad.com and my client it's client.dom.gi.in.

I managed to deploy the client without any problems.

 

I manage to make the selection. But when I run the job I have the following message

[Major] From: BSM@cell.ad.com "test"  Time: 6/11/2012 11:19:39 AM
[61:3003]      Lost connection to VBDA named "D: [Data]"
    on host client.dom.gi.in.
    Ipc subsystem reports: "IPC Read Error
    System error: [10053] Software caused connection abort
"

[Major] From: BSM@cell.ad.com "test"  Time: 6/11/2012 11:19:45 AM
[61:3003]      Lost connection to VBDA named "D: [Data]"
    on host client.dom.gi.in.
    Ipc subsystem reports: "IPC Read Error
    System error: [10053] Software caused connection abort
"

I tried several things without success.

How you configure your backup in another domain?

 

Bests Regards

Please use plain text.
Frequent Advisor
Le Coq Manuel
Posts: 53
Registered: ‎09-03-2009
Message 2 of 23 (10,049 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

I find the solution.

 

We must put the following value OB2INETTIMEOUT=10 in the file of the client omnirc

 

http://www.data-protector.org/wordpress/2012/05/dp-7-0-omnirc-variable/

 

Data protector 7.0

 

Bests Regards

Please use plain text.
Occasional Advisor
best_hp
Posts: 10
Registered: ‎08-01-2012
Message 3 of 23 (9,769 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

I have same problem, but this solution not working for me.....

Please use plain text.
Occasional Visitor
pesosh
Posts: 1
Registered: ‎08-15-2012
Message 4 of 23 (9,742 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi,



best_hp, try to restart Data Protector services of the Client and Cell Manager.



It helped me!



Best Regards, Pavel
Please use plain text.
Honored Contributor
Eblyn Solis
Posts: 1,307
Registered: ‎10-19-2007
Message 5 of 23 (9,690 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

hi,

 

These types of errors tell us there was a network problem during the backup that prevented Data Protector from maintaining an open connection between the cell server, disk and media agents, and therefore the backup was aborted.  Data Protector is reporting the problem but usually Data Protector itself is functioning correctly.

 

Poor network performance causes overloaded connections between Disk Agent systems and the Media Agent system, resulting in connection drops and finally the session timeouts and the backup is aborted.

 

try with this variable: 

 

- Activate omnirc by renaming to lose Template extension.

 

UNIX systems   /opt/omni/mv .omnirc.TMPL .omnirc

WINDOWS   \Program Files\OmniBack>copy omnirc.TMPL omnirc

 

Add the following uncommented statements to the system's omnirc file:

 

OB2IPCKEEPALIVE=1

OB2SHMIPC=0

 

Details:

 

OB2IPCKEEPALIVE=1 to all clients DA + MA.  The keepalive parameter just turns on the system mechanism for keeping connection alive for all the connection we make.

 

OB2SHMIPC=0 should be set on the cell manager and all client systems (at least to the systems reporting Critical and Abort errors).  Improves handling of shared memory and may improve Network throughput.

 

 

 

Regards

 

Please use plain text.
Occasional Visitor
jb_adhoc
Posts: 1
Registered: ‎10-09-2012
Message 6 of 23 (9,322 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

this one worked for me with DataProtector 7.0

 

the problem was only on a windows 2003 R2 SP1 32b client .

Please use plain text.
Valued Contributor
Syedfurquan
Posts: 360
Registered: ‎09-19-2011
Message 7 of 23 (8,934 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hello ,

 

I am using DP 7 with cell manager on windows 2008R2. I am also getting same error as mentioned above on few servers and try to edit the variable,

OB2IPCKEEPALIVE=1

OB2SHMIPC=0

in the omnirc file, but could not find the defined value as above. I checked both on client and cell manager and couldn't find any entry of the the variable in the file.

 

Any help?

Regards

Please use plain text.
Valued Contributor
jruffer
Posts: 168
Registered: ‎06-28-2011
Message 8 of 23 (8,928 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

That's OK, you can add it at the end.

 

Jeremy

Please use plain text.
Valued Contributor
Syedfurquan
Posts: 360
Registered: ‎09-19-2011
Message 9 of 23 (8,924 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hello Jeremy,

 

Thanks for the reply... I need to add these variable on client omnirc file or cell manager or on both.

 

 

Please use plain text.
Honored Contributor
Eblyn Solis
Posts: 1,307
Registered: ‎10-19-2007
Message 10 of 23 (8,917 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

hi

 

add in both servers.

Please use plain text.
Honored Contributor
Stephan.
Posts: 512
Registered: ‎10-31-2002
Message 11 of 23 (8,914 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

To edit the files you might like http://hpux.de/category/DPcfgCreator/

 

Includes the most relevant recommended settings for a DP 7.x cell manager and can create the config files for all clients.

 

hth,

Stephan

Please use plain text.
Valued Contributor
Syedfurquan
Posts: 360
Registered: ‎09-19-2011
Message 12 of 23 (8,905 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hello All,

 

Tried to rename the omnirc.tmpl file to omnirc and then added the entry of

OB2IPCKEEPALIVE=1

OB2SHMIPC=0

 

on client & cell manager but still backup failing.

 

Any help

 

Regards,

Please use plain text.
Valued Contributor
Syedfurquan
Posts: 360
Registered: ‎09-19-2011
Message 13 of 23 (8,852 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi,

 

made an entry of client in the hosts file of cell manager and it starts working fine.

Please use plain text.
Advisor
ICT Backoffice
Posts: 15
Registered: ‎02-16-2009
Message 14 of 23 (8,389 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

I have to check the option Publish PTR records in my Windows 2008 R2 Cluster Name resource
Please use plain text.
Regular Advisor
Lois Morrett
Posts: 108
Registered: ‎02-23-2009
Message 15 of 23 (8,205 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Thank you for the information. Putting client name and ip address in hosts file on cell server fixed this for me too !!

Please use plain text.
Visitor
GSSIT
Posts: 4
Registered: ‎11-24-2011
Message 16 of 23 (8,030 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

addint the two suggested settings to the omniirc file worked for me

Please use plain text.
Honored Contributor
Eblyn Solis
Posts: 1,307
Registered: ‎10-19-2007
Message 17 of 23 (8,010 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi,

 

Looks like this variable fix the problem on DP 7.xx

 

OB2SHMIPC=0
OB2IPCKEEPALIVE=1
OB2INETTIMEOUT=10
OB2IPCKEEPALIVETIME=900
OB2IPCKEEPALIVEINTERVAL=60

 

Regards

Please use plain text.
Occasional Visitor
IM-Supply
Posts: 1
Registered: ‎10-03-2013
Message 18 of 23 (4,591 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

OB2NOTREEWALK=1
OB2INETTIMEOUT=120
OB2IPCKEEPALIVE=1
OB2IPCKEEPALIVETIME=900
OB2IPCKEEPALIVEINTERVAL=60
OB2SHMIPC=0

 

Adding the above setting to the client and adding the servername and IP in the cellmanager HOSTS file solved our problem with this error!

 

Thanx all for trying en solving this problem :-)

Please use plain text.
Occasional Visitor
SYKH
Posts: 1
Registered: ‎10-17-2013
Message 19 of 23 (4,322 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi , 

 

I found the omnirc.TMPL file located in Cell Manager directory C:\ProgramData\OmniBack\omnirc.TMPL

HP Data Protector product version is A.06.20, internal build version is 400.

 

Rename in the same directory like example:

C:\ProgramData\OmniBack\omnirc.TMPL --> omnirc OR copy and rename to C:\Program Files\OmniBack\omnirc ?

 

 

Please use plain text.
Honored Contributor
Eblyn Solis
Posts: 1,307
Registered: ‎10-19-2007
Message 20 of 23 (4,288 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

hi,

 

Just created a newone omnirc file without extenxion, and put inside the variables.

 

and yes created on  C:\Program Files\OmniBack\

 

Regards

Please use plain text.
Occasional Visitor
Techbrain
Posts: 3
Registered: 2 weeks ago
Message 21 of 23 (287 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort


Eblyn Solis wrote:

hi

 

add in both servers.


Hi,  do i have to go to each and every client and edit this file individually or can i just edit one on one of the clients and the simply copy it to all other clients?  (in other words does ths file contains specific local information for each client? or is it a general file that is simply copied to all clients during the installation?)

 

also i have DP8.10 is this solution is applicable for my version as well? (since i am experiencing the same problems)

 

thanks in advance.

Please use plain text.
Occasional Visitor
Techbrain
Posts: 3
Registered: 2 weeks ago
Message 22 of 23 (191 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort


Eblyn Solis wrote:

hi,

 

Just created a newone omnirc file without extenxion, and put inside the variables.

 

and yes created on  C:\Program Files\OmniBack\

 

Regards


Hi guys, just a bit confused here,  should i put the new created file to" c:\Program Files\Omniback or to C:\Program Data\Omniback ?? 

thank you.

Please use plain text.
Honored Contributor
Eblyn Solis
Posts: 1,307
Registered: ‎10-19-2007
Message 23 of 23 (164 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi,

 

the 'omnirc' file does not exist by default. It has to be created on Windows by opening a blank Notepad 

makintg sure that the filename has no extension, like 'txt' or 'tmpl'.

 

On W2008 or 2012 is on  C:\ProgramData\Omniback 

 

and only create on servers that you have problems, no in all servers

 

 

 

Regards

 

 

 

Please use plain text.
The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation