Re: IPC Read Error System error: [10053] Software caused connection abort (13415 Views)
Reply
Frequent Advisor
Posts: 53
Registered: ‎09-03-2009
Message 1 of 28 (14,562 Views)
Accepted Solution

IPC Read Error System error: [10053] Software caused connection abort

hI,

 

Im a cell manager cell.ad.com and my client it's client.dom.gi.in.

I managed to deploy the client without any problems.

 

I manage to make the selection. But when I run the job I have the following message

[Major] From: BSM@cell.ad.com "test"  Time: 6/11/2012 11:19:39 AM
[61:3003]      Lost connection to VBDA named "D: [Data]"
    on host client.dom.gi.in.
    Ipc subsystem reports: "IPC Read Error
    System error: [10053] Software caused connection abort
"

[Major] From: BSM@cell.ad.com "test"  Time: 6/11/2012 11:19:45 AM
[61:3003]      Lost connection to VBDA named "D: [Data]"
    on host client.dom.gi.in.
    Ipc subsystem reports: "IPC Read Error
    System error: [10053] Software caused connection abort
"

I tried several things without success.

How you configure your backup in another domain?

 

Bests Regards

Frequent Advisor
Posts: 53
Registered: ‎09-03-2009
Message 2 of 28 (14,550 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

I find the solution.

 

We must put the following value OB2INETTIMEOUT=10 in the file of the client omnirc

 

http://www.data-protector.org/wordpress/2012/05/dp-7-0-omnirc-variable/

 

Data protector 7.0

 

Bests Regards

Occasional Advisor
Posts: 10
Registered: ‎08-01-2012
Message 3 of 28 (14,270 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

I have same problem, but this solution not working for me.....

Occasional Visitor
Posts: 1
Registered: ‎08-15-2012
Message 4 of 28 (14,243 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi,



best_hp, try to restart Data Protector services of the Client and Cell Manager.



It helped me!



Best Regards, Pavel
Honored Contributor
Posts: 1,350
Registered: ‎10-19-2007
Message 5 of 28 (14,191 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

hi,

 

These types of errors tell us there was a network problem during the backup that prevented Data Protector from maintaining an open connection between the cell server, disk and media agents, and therefore the backup was aborted.  Data Protector is reporting the problem but usually Data Protector itself is functioning correctly.

 

Poor network performance causes overloaded connections between Disk Agent systems and the Media Agent system, resulting in connection drops and finally the session timeouts and the backup is aborted.

 

try with this variable: 

 

- Activate omnirc by renaming to lose Template extension.

 

UNIX systems   /opt/omni/mv .omnirc.TMPL .omnirc

WINDOWS   \Program Files\OmniBack>copy omnirc.TMPL omnirc

 

Add the following uncommented statements to the system's omnirc file:

 

OB2IPCKEEPALIVE=1

OB2SHMIPC=0

 

Details:

 

OB2IPCKEEPALIVE=1 to all clients DA + MA.  The keepalive parameter just turns on the system mechanism for keeping connection alive for all the connection we make.

 

OB2SHMIPC=0 should be set on the cell manager and all client systems (at least to the systems reporting Critical and Abort errors).  Improves handling of shared memory and may improve Network throughput.

 

 

 

Regards

 

Occasional Visitor
Posts: 1
Registered: ‎10-09-2012
Message 6 of 28 (13,823 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

this one worked for me with DataProtector 7.0

 

the problem was only on a windows 2003 R2 SP1 32b client .

Trusted Contributor
Posts: 407
Registered: ‎09-19-2011
Message 7 of 28 (13,435 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hello ,

 

I am using DP 7 with cell manager on windows 2008R2. I am also getting same error as mentioned above on few servers and try to edit the variable,

OB2IPCKEEPALIVE=1

OB2SHMIPC=0

in the omnirc file, but could not find the defined value as above. I checked both on client and cell manager and couldn't find any entry of the the variable in the file.

 

Any help?

Regards

Trusted Contributor
Posts: 189
Registered: ‎06-28-2011
Message 8 of 28 (13,429 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

That's OK, you can add it at the end.

 

Jeremy

Trusted Contributor
Posts: 407
Registered: ‎09-19-2011
Message 9 of 28 (13,425 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hello Jeremy,

 

Thanks for the reply... I need to add these variable on client omnirc file or cell manager or on both.

 

 

Honored Contributor
Posts: 1,350
Registered: ‎10-19-2007
Message 10 of 28 (13,418 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

hi

 

add in both servers.

Honored Contributor
Posts: 512
Registered: ‎10-31-2002
Message 11 of 28 (13,415 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

To edit the files you might like http://hpux.de/category/DPcfgCreator/

 

Includes the most relevant recommended settings for a DP 7.x cell manager and can create the config files for all clients.

 

hth,

Stephan

Trusted Contributor
Posts: 407
Registered: ‎09-19-2011
Message 12 of 28 (13,406 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hello All,

 

Tried to rename the omnirc.tmpl file to omnirc and then added the entry of

OB2IPCKEEPALIVE=1

OB2SHMIPC=0

 

on client & cell manager but still backup failing.

 

Any help

 

Regards,

Trusted Contributor
Posts: 407
Registered: ‎09-19-2011
Message 13 of 28 (13,353 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi,

 

made an entry of client in the hosts file of cell manager and it starts working fine.

Advisor
Posts: 15
Registered: ‎02-16-2009
Message 14 of 28 (12,890 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

I have to check the option Publish PTR records in my Windows 2008 R2 Cluster Name resource
Regular Advisor
Posts: 108
Registered: ‎02-23-2009
Message 15 of 28 (12,706 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Thank you for the information. Putting client name and ip address in hosts file on cell server fixed this for me too !!

Visitor
Posts: 4
Registered: ‎11-24-2011
Message 16 of 28 (12,531 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

addint the two suggested settings to the omniirc file worked for me

Honored Contributor
Posts: 1,350
Registered: ‎10-19-2007
Message 17 of 28 (12,511 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi,

 

Looks like this variable fix the problem on DP 7.xx

 

OB2SHMIPC=0
OB2IPCKEEPALIVE=1
OB2INETTIMEOUT=10
OB2IPCKEEPALIVETIME=900
OB2IPCKEEPALIVEINTERVAL=60

 

Regards

Occasional Visitor
Posts: 1
Registered: ‎10-03-2013
Message 18 of 28 (9,092 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

OB2NOTREEWALK=1
OB2INETTIMEOUT=120
OB2IPCKEEPALIVE=1
OB2IPCKEEPALIVETIME=900
OB2IPCKEEPALIVEINTERVAL=60
OB2SHMIPC=0

 

Adding the above setting to the client and adding the servername and IP in the cellmanager HOSTS file solved our problem with this error!

 

Thanx all for trying en solving this problem :-)

Occasional Visitor
Posts: 1
Registered: ‎10-17-2013
Message 19 of 28 (8,823 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi , 

 

I found the omnirc.TMPL file located in Cell Manager directory C:\ProgramData\OmniBack\omnirc.TMPL

HP Data Protector product version is A.06.20, internal build version is 400.

 

Rename in the same directory like example:

C:\ProgramData\OmniBack\omnirc.TMPL --> omnirc OR copy and rename to C:\Program Files\OmniBack\omnirc ?

 

 

Honored Contributor
Posts: 1,350
Registered: ‎10-19-2007
Message 20 of 28 (8,789 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

hi,

 

Just created a newone omnirc file without extenxion, and put inside the variables.

 

and yes created on  C:\Program Files\OmniBack\

 

Regards

Occasional Visitor
Posts: 3
Registered: ‎07-09-2014
Message 21 of 28 (4,788 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort


Eblyn Solis wrote:

hi

 

add in both servers.


Hi,  do i have to go to each and every client and edit this file individually or can i just edit one on one of the clients and the simply copy it to all other clients?  (in other words does ths file contains specific local information for each client? or is it a general file that is simply copied to all clients during the installation?)

 

also i have DP8.10 is this solution is applicable for my version as well? (since i am experiencing the same problems)

 

thanks in advance.

Occasional Visitor
Posts: 3
Registered: ‎07-09-2014
Message 22 of 28 (4,692 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort


Eblyn Solis wrote:

hi,

 

Just created a newone omnirc file without extenxion, and put inside the variables.

 

and yes created on  C:\Program Files\OmniBack\

 

Regards


Hi guys, just a bit confused here,  should i put the new created file to" c:\Program Files\Omniback or to C:\Program Data\Omniback ?? 

thank you.

Honored Contributor
Posts: 1,350
Registered: ‎10-19-2007
Message 23 of 28 (4,665 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi,

 

the 'omnirc' file does not exist by default. It has to be created on Windows by opening a blank Notepad 

makintg sure that the filename has no extension, like 'txt' or 'tmpl'.

 

On W2008 or 2012 is on  C:\ProgramData\Omniback 

 

and only create on servers that you have problems, no in all servers

 

 

 

Regards

 

 

 

Occasional Visitor
Posts: 2
Registered: ‎07-30-2014
Message 24 of 28 (4,335 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

Hi, this is a bit late to comment but I have the same problem and do not understand how to fix it.

 

A file is created from the windows notepad and saved to the path C:\ProgramData\OmniBack or C:\ProgramFiles\OmniBack? and saved with the name "omnirc" without extension.

 

Only variables should add or anything containing "omnirc.tmpl" file?

 

Thanks for your answers.

 

Regards

Honored Contributor
Posts: 1,350
Registered: ‎10-19-2007
Message 25 of 28 (4,332 Views)

Re: IPC Read Error System error: [10053] Software caused connection abort

hi,

 

just created and put the variables .

the file omnirc.tmpl  is just template don't use.

 

Regards

 

The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation.