Re: DP8.1 upgrade (497 Views)
Reply
Frequent Advisor
A_C
Posts: 48
Registered: ‎05-04-2010
Message 1 of 4 (532 Views)
Accepted Solution

DP8.1 upgrade

We just upgraded from DP 8  to DP 8.1.  Now to get into the GUI it is asking for a user name and password.  Is this something we need to request from HP or is there a default out there?

Frequent Advisor
A_C
Posts: 48
Registered: ‎05-04-2010
Message 2 of 4 (517 Views)

Re: DP8.1 upgrade

Steps:

1. Stop the services.
2. Create a new certificate using the following command:

"Program Files\OmniBack\bin\perl.exe" "\Program Files\Omniback\bin\omnigencert.pl" -server_id <full qualified DNS/host name> -user_id HPDP -store_password <keystorePassword> -server_san ip:<IP address>

3. Start the services.
4. Try to access the GUI again.

The keystorePassword can be found at:

<ProgramData\OmniBack>\Config\client\components\webservice.properties
Honored Contributor
danielbraun
Posts: 752
Registered: ‎07-07-2010
Message 3 of 4 (497 Views)

Re: DP8.1 upgrade

Hi,

 

if not working, name resolution might be the root cause. Check if cell server can be resolved properly, short, fqdn, reverse. After that try a repair installation or just generate a new certificate.

 

Best regards

Daniel

-----------
Please assign Kudos - How to assign...
Super Advisor
ThierryT
Posts: 304
Registered: ‎06-05-2009
Message 4 of 4 (309 Views)

Re: DP8.1 upgrade

Just side q

 

if the certificate is corrupted or deleted etc...does the same command to be re-run again to recreate/regenerate or have to safekeep/backup the certificate and restore when such situation happens?

 

 

The opinions expressed above are the personal opinions of the authors, not of HP. By using this site, you accept the Terms of Use and Rules of Participation.