Re: Error on dashboard 360 degree view page (1094 Views)
Reply
Honored Contributor
Posts: 2,416
Registered: ‎01-23-2010
Message 1 of 5 (1,109 Views)

Error on dashboard 360 degree view page

Hi ,

while acessing particular dashboard 360 degree view page we are getting internal system error

while looking at the logs we see

2011-06-16 09:21:55,305 [ajp-0.0.0.0-8009-4] (BACDataProvider.java:122) ERROR - failed to init dashboard
java.io.IOException: Server returned HTTP response code: 500 for URL: http://localhost:8080/topaz/dashboard/arch/CreateDashboardModuleList.jsp;jsessionid=6B3B76A86911CC5BFAE2D1C0B9993B
Cheers!

Nvr Blame a day in ur life....... Good day gives "happiness" & Bad day gives "experience" ......
Regular Advisor
Posts: 136
Registered: ‎05-14-2003
Message 2 of 5 (1,105 Views)

Re: Error on dashboard 360 degree view page

we are getting the same error, did you figure this out?

Honored Contributor
Posts: 2,416
Registered: ‎01-23-2010
Message 3 of 5 (1,095 Views)

Re: Error on dashboard 360 degree view page

Please clear jboss cache and check
Cheers!

Nvr Blame a day in ur life....... Good day gives "happiness" & Bad day gives "experience" ......
Regular Advisor
Posts: 136
Registered: ‎05-14-2003
Message 4 of 5 (1,094 Views)

Re: Error on dashboard 360 degree view page

got help from HP Support. we were given the resolution below :


1. on the BAC server, copy the three folders in C:\HPBSM\conf\uimashup\import\loaded to C:\HPBSM\conf\uimashup\import\toload.

2. on the BAC server, rename the three folders in C:\HPBSM\conf\uimashup\import\loaded and then create the three folders again, but empty.

3. launch JMX console, navigate to Foundations->service=UIMDataLoader

4. invoke loadAllData() with a value of 1.

5. invoke loadComponentsGallery() with a value of 1.

6. invoke loadEvents() with a value of 1.

7. invoke loadPagesData() with a value of 1.

 

 

Valued Contributor
Posts: 410
Registered: ‎02-02-2011
Message 5 of 5 (655 Views)

Re: Error on dashboard 360 degree view page

Hello All,

 

I was able to perform these steps on my TEST and DEV BSM servers and worked great, but for my PROD BSM environmnet I still get the "Internal Error" when viewing 360 VIew for SYstem Monitors view. I do not get this error for any of my other 360 views.

 

Does anyone have a clue as to what else to check ofr?

 

Are there any configuration settings I can cahnge that maybe are not allowing the amount of monitors to be viewed in this 360 View?

 

Any ideas or suggestions greatly appreciated.

 

THanks in advance.

Tex2020